Setup
Operating Instructions 867 - 04.0 - 03/2018 125
Switch position on the circuit board
Fig. 76: Switch position on the circuit board
The position of the switch (1) depends on the subclass:
Machines with a binder: Position 1
Machines with switchable needle bars: Position 2
Machines with a clean seam start:
Additional Instructions 0791 867708
7.12.9 Setting machine-specific parameters
With DAC controls the parameters are automatically set via
transfer of the machine ID.
With Efka controls the parameter F-290 must be set for each
subclass according to the specifications in Parameter sheet.
The parameter sheet is provided in the control accessory pack.
To set the machine-specific parameters:
1. Set parameter F-290 according to the specifications in
Parameter sheet.
For subclass 867-290342-100 only:
2. Set parameter F-111 to 2500 min
-1
or less.
(1) - Switch
p

Table of Contents

Other manuals for DURKOPP ADLER 867

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DURKOPP ADLER 867 and is the answer not in the manual?

DURKOPP ADLER 867 Specifications

General IconGeneral
Stitch TypeLockstitch
Max Stitch Length12 mm
Needle System134-35
Needle Thread TensionAdjustable
LubricationAutomatic
TypeIndustrial Sewing Machine
Max Sewing Speed3000 stitches per minute
Presser Foot Lift20 mm
Power Requirements230V/50Hz