EasyManuals Logo

DURKOPP ADLER 867 Durkopp Adler

DURKOPP ADLER 867
192 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #147 background imageLoading...
Page #147 background image
Troubleshooting
Operating Instructions 867 - 04.0 - 03/2018 145
3105 Error U24 V short circuit Disconnect 37-pin plug
Replace control if error
is not corrected
Test inputs/outputs for
24 V short circuit
3106 Error
U24 V (I
2
T) overload
One or several
magnets defective
3107 Error Pedal not connected Connect analog pedal
3109 Warning Operation lock Check tilt sensor on
machine
3151 Warning Maintenance necessary
(operation cannot
continue unless
parameter t5114 is
reset)
Service is urgently
required Service
Instructions
6353 Error Internal EEprom
communication error
Switch off the control
Wait until the LEDs are
off
Switch the machine
back on
6354 Error External EEprom
communication error
Switch off the control
Wait until the LEDs are
off
Check machine ID
connection
Switch the control back
on
8401 Error Watchdog Software update
Machine ID reset
Replace the control
Code
Error/
warning
Possible cause Remedial action

Table of Contents

Other manuals for DURKOPP ADLER 867

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DURKOPP ADLER 867 and is the answer not in the manual?

DURKOPP ADLER 867 Specifications

General IconGeneral
Stitch TypeLockstitch
Max Stitch Length12 mm
Needle System134-35
Needle Thread TensionAdjustable
LubricationAutomatic
TypeIndustrial Sewing Machine
Max Sewing Speed3000 stitches per minute
Presser Foot Lift20 mm
Power Requirements230V/50Hz