EPSON Stylus Pro 4400/4450/4800/4880/4880C Revision C
Troubleshooting Troubleshooting Based on Panel Messages 184
SERVICE REQ. 00010012
Error meaning:
CR overload (high sensitivity) error
Explanation
PWM has been being output for a certain period of time. This can be made
when load on the CR Motor is slightly increased.
Remedy / Points to be checked
1. Check the load on the CR Motor.
Running load of CR Motor (check by manual operation)
Measure the resistance value of the PF Motor.
If the CR Motor is found in short mode, replace the BOARD ASSY.,
MAIN at the same time.
Damage to or wear in the CR Driven Pulley
Damaged or worn bearing of the Carriage Unit
Flaws in the CR Rail caused by roller running
Tension of the CR timing belt
2. Replace the Motor Assy., CR (p.270)
3. Replace the C593 MAIN Board (p.226)
SERVICE REQ. 00010013
Error meaning:
PF overload (high sensitivity) error
Explanation
PWM has been being output for a certain period of time. This can be made
when load on the PF Motor is slightly increased.
Remedy / Points to be checked
1. Check the load on the PF Motor.
Measure the resistance value of the PF Motor.
If the PF Motor is found in short mode, replace the BOARD ASSY.,
MAIN at the same time.
Running load of PF Motor (check by manual operation)
Rotation load of PF Motor
2. Replace the Motor Assy., PF (p.349)
3. Replace the C593 MAIN Board (p.226)