Disassembly & Assembly Disassembly Procedures 354
4.2.9.6 Rear Manual Insertion Sensor
1. Remove "Holder, Roller, Unit" (p214).
2. Remove "Paper Guide Assy., M, SP" (p215).
3. Release "Rear Manual Insertion Sensor" harness from the two tabs.
(Refer to Figure 4-216.)
4. Release "Guide, Roll Paper" along with "Rear Manual Insertion Sensor".
(Refer to "4.2.9.1 Release Unit" (p343).)
5. Remove the screw securing "Installation Plate, Detector, Rear" and
remove "Installation Plate, Detector, Rear".
(Refer to Figure 4-217.)
C.B.P. 3x8: 1 pc.
Figure 4-216. Releasing the Harness
Figure 4-217. Installation Plate, Detector, Rear Removal
Align the two dowels of holder with the two frame
positioning holes. (Refer to Figure 4-217.)
Do not let the harness slip in "Installation Plate,
Detector, Rear". (Refer to Figure 4-216.)
Harness Installation Plate, Detector, Rear
Tabs
Dowels and Installation Holes