EPSON Stylus Pro 4400/4450/4800/4880/4880C Revision C
Disassembly & Assembly Disassembly Procedures 317
6. Remove the two screws securing the "Shaft, Transmission, PG Unit" and
then remove the "Shaft, Transmission, PG Unit" by pulling it out of the hole
in the frame. (Refer to Figure 4-155.)
C.B.S. 3x6: 2 pcs.
Figure 4-155. Shaft, Transmission, PG Unit Removal
C A U T I O N
Be careful not to scratch the "Shaft, Transmission, PG Unit"
gear by bumping it against the frame.
Align "Shaft, Transmission, PG Unit" positioning hole
with dowel on frame. (Refer to Figure 4-155.)
Make sure that the "Pump Phase Sensor" harness is
routed over the "Shaft, Transmission, PG Unit" shaft.
(Refer to Figure 4-155.)
Dowel and Positioning Hole
C.B.S. 3x6
Harness