EasyManua.ls Logo

Epson Stylus Pro 4450 - I;H Right Unit Removal; I;H Lever Sensor (Right) Removal

Epson Stylus Pro 4450
506 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EPSON Stylus Pro 4400/4450/4800/4880/4880C Revision C
Disassembly & Assembly Disassembly Procedures 313
18. Pull the "I/H Right Unit" forward from the printer following the order below
while pulling the "Harness, CSIC" and "I/H Lever Sensor (Right)" harness
from the hole in the frame. (Refer to Figure 4-150.)
18-1. To avoid interference of the printer frame hole and "I/H Right Unit"
shaft, shift the "I/H Right Unit" to the left.
18-2. With the right side of the "Paper Eject Unit" lifted up, pull the "I/H
Right Unit" forward from the printer.
19. Pick up and release the two hooks securing the "I/H Lever Sensor (Right)"
and then remove the "I/H Lever Sensor (Right)". (Refer to Figure 4-151.)
20. Disconnect connector from "I/H Lever Sensor (Right)".
(Refer to Figure 4-151.)
Figure 4-150. I/H Right Unit Removal
Figure 4-151. I/H Lever Sensor (Right) Removal
The four grounding springs on the top of the "I/H Right Unit"
make contact with the printer frame, so install the "I/H Right
Unit" while lightly holding down the grounding springs so as
not to deform them.
Grounding Springs
Step 18-1
Shaft and Frame interference
1
2
3
Paper Eject Unit
Pull harness through this hole
Hooks
I/H Lever Sensor (Right)
Connector

Table of Contents

Other manuals for Epson Stylus Pro 4450