EPSON Stylus Pro 4400/4450/4800/4880/4880C Revision C
Disassembly & Assembly Disassembly Procedures 357
4.2.9.9 PF Encoder Sensor
1. Remove "Cover, Side, Left" (p216).
2. Remove the two screws securing the "PF Encoder Sensor".
C.P.P. 2.6x8: 2 pcs.
3. Disconnect the connector from the "PF Encoder Sensor" and then remove
the "PF Encoder Sensor".
Figure 4-222. PF Encoder Sensor Removal
C A U T I O N
Be careful not to deform or damage the "Scale, PF" attached
to the "Pulley, Roller, PF".
Align the two dowels of the "PF Encoder Sensor" with
the two positioning holes on the "Holder,Sensor.
Do not bend condenser. (Refer to Figure 4-222.)
After installing the "PF Encoder Sensor", confirm that
the "PF Scale" is surely inserted into the sensor slit.
Confirm that the "PF Scale" is not contacting the sensor.
DowelsPositioning Holes
A D J U S T M E N T
R E Q U I R E D
Be sure to refer to Chapter 5 “Adjustment” (p.366) and
perform specified adjustments after replacing the "PF
Encorder Sensor".
PF Scale
PF Encoder Sensor
Connector
Condenser
C.P.P. 2.6x8