Fluke 990DSL - Setting up a VF Noise Test; VF Noise Test

Fluke 990DSL
242 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
990DSL
Users Guide
4-40
VF Noise Test
This test performs a “snapshot” measurement of the voice frequency Metallic
Noise (Nm) and Power Influence (PI) on the pair.
Setting Up a VF Noise Test
To set up a VF Noise test, select the test on the POTS Toolbox and press
D(
Setups).
Refer to Table 4-7 for VF Noise test setup parameters.
Table 4-7. VF Noise Test Setup Parameters
Parameter Settings (default in bold)
Termination Impedance 600 e or 900 e
Termination Mode Terminated or Bridged
Measurement Filter C-Msg, C-Notched, 3K Flat, 15K Flat
Nm Pass Threshold 30 dBrn (Range = 0 to 99)
P.I. Pass Threshold 80 dBrn (Range = 0 to 99)
Power Harmonics Units dBm or dBrn
PH C-Message Filter No or Yes