EasyManua.ls Logo

Fluke 990DSL - User-Selectable Tests for the POTS Auto-Test

Fluke 990DSL
242 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
990DSL
Users Guide
4-4
Table 4-1. User-Selectable Tests for the POTS Auto-Test
Test Description Settings (default in bold)
Voltage Measures AC and DC
voltages on all legs of
spare or working pairs.
No choice, always run.
Shorts & Grounds Measures resistance
between all legs of spare
pairs.
No choice, always run.
(N/A on working pairs)
Opens Measures capacitance on
spare pairs, converting to
distance based on the
Cable Type selected.
Select Y to enable the test
Select N to disable the test.
(N/A on working pairs)
Load Coils Detects the number of
coils and approximate
distance to the first, on
spare or working POTS
pairs, plus a frequency
response graph.
Select Y to enable the test
Select N to disable the test.
Loop Devices Detects the presence of
loop treatment devices,
fault-sectionalizing
devices, and Mechanical
Bell Ringers on spare or
working POTS pairs.
Select Y to enable the test
Select N to disable the test.
VF Long. Balance Measures resistive and
capacitive balance of the
pair to Ground, on spare
or working POTS pairs.
Select Y to enable the test
Select N to disable the test.
Loop Current Measures Loop Current,
Ring-Ground Current, and
cable sheath Ground
resistance on working
POTS pairs.
Select Y to enable the test
Select N to disable the test.
(N/A on spare pairs)

Table of Contents

Related product manuals