Setting Up and Operating the CopperPro
The Menus
3
3-7
Table 3-1. Generic Setup Parameters
Parameter Description
Facility Cable No. This number identifies the cable name of the pair on
which the test is being conducted.
In the highlighted field, supply the alphanumeric
cable name (up to 24 characters maximum).
Pair/Terminal No. This number identifies the specific single cable pair,
the cross-box binding post, or the inside terminal
number on which the test is being conducted.
In the highlighted field, supply the number (five digits
maximum).
CopperPro Pair No. This number identifies the CopperPro test lead pair.
In the highlighted field, type a 1 (for T & R) or a 2 (for
T1 & R1, if no external multiple-pair access modules
are attached).
Editing the Setup for a Test
To edit the setup for a test, complete the following:
1. To change the value of a generic parameter, refer to the information in
Table 3-1 and complete the following for each parameter you want to
change:
a) Press F or H to select the parameter. Then, press A(
Edit).
The tester is now in Edit mode.
b) In the highlighted field, use the keypad to type the desired value.
When you finish, press L.
The values are saved in the tester’s memory and apply to all
CopperPro tests until you change them.