POTS Testing and Fault Location
Dial-Up Test Group
4
4-59
Smart-Pro Tests
The tests in this group enable the tester to dial a C.O.-based Fluke Networks
Smart-Pro unit and run various VF tests over a working POTS line.
The following procedure shows you how to dial a Smart-Pro and run a 10-
Tone Slope test. Other Smart-Pro tests are performed in a similar manner.
To run a 10-Tone Slope test, do the following:
1. From the Dial-Up Test Toolbox, select
Smart-Pro Tests and press
L.
The
Smart-Pro Menu is displayed, with tests listed in Table 4-15:
Table 4-15. Smart-Pro Tests
Test Description
N-Tone Slope The Smart-Pro applies a sequential set of
3, 10, or 30 tones to the line. The
CopperPro tester measures the
Frequency, Loss, and Slope of these
tones.
SmartTone Loss
The Smart-Pro applies a composite set of
100 VF tones to the line. The CopperPro
tester measures and displays a VF Loss
Graph.
Quiet Term. VF Noise The Smart-Pro applies a quiet termination
to the line for 20 seconds. The CopperPro
tester measures Nm and P.I. on the pair.
Caller ID Callback The Smart-Pro receives a command to
return a call back to the test line. It then
issues a 3 second audible tone to prompt
you to hang up for the return call.
Press L to hang up. The tester then
automatically captures and displays
Caller ID information sent during the call.