Saving Test Results
Saving Test Results
7
7-5
2. Press A (Edit) then For H to change the automatic test storage setting
to Disabled.
The tester no longer automatically stores test results.
Saving a Displayed Waveform or Frequency Graph
To save a TDR waveform or frequency sweep graph, do the following:
1. Make sure that the TDR waveform or frequency sweep graph that you
want to save is displayed on the tester’s LCD.
2. Press L.
The list of saved waveforms (see Figure 7-4) or frequency graphs (see
Figure 7-5) is displayed.
3. Press F or H move the cursor to the desired storage position (1 through
10 for a TDR waveform and 1 or 2 for a frequency sweep graph).
4. If you want to make some notes about the waveform or graph, press
A(
Edit Remarks). Then, type your notes in the space provided.
5. Press B(
Save).
The waveform or graph is saved in the storage position you selected. The
tester also saves the associated setup information (for example, Vop,
Pulsewidth, Cursor positions, and Filters employed).