Fluke 990DSL - Running a Terminated VF Test; Setting up a Terminated VF Test

Fluke 990DSL
242 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
990DSL
Users Guide
4-68
Tip, Ring, Loop and Ground Resistance
Resistive Unbalance
10-Tone Slope (TN2000 Terminator, FED
, FEDII
, and Helper
)
SmartTone Loss & Slope (TN2100 Terminator or TN2200 Terminator II)
Setting Up a Terminated VF Test
To set up a test, complete the following:
1. Set the Pass thresholds for each individual test (see previous list).
2. Set up the Auto-Test. Do the following:
a) From the POTS Toolbox, select
Terminated VF Tests and press L.
b) From the
Select Terminated Test Type screen, press D(Setups).
c) Enter a setting for Loop Resistance, Ground Resistance, and
Unbalance Resistance Pass Thresholds.
Running a Terminated VF Test
This procedure shows you how to run a Terminator VF Auto-Test. You
can use this procedure to run the Terminated VF Test with any of the
other far-end devices listed.
To run a Terminated VF Test, do the following:
1. From
Select Terminated Test Type, press A(Terminator VF Auto-Test).
The Terminator VF Auto-Test connection diagram is displayed as shown
in Figure 4-33: