Setting Up and Operating the CopperPro
Performing Basic Operations
3
3-23
Operating the Tester as a Dial Set
To operate the CopperPro as a dial set, do the following:
1. Turn on the CopperPro.
2. Connect the T (Tip) and R (Ring) test leads to a working POTS line. If the
line is a ground-start line (as opposed to loop-start), connect the G
(Ground) test lead to the cable sheath or C.O. ground.
3. Press ?.
The Dialing Mode Selection screen is displayed.
4. Do one of the following:
To automatically dial the number, press A(
Auto-Dial). Select the
number from the list, then press K.
To manually dial the number, press B(
Manual Dial). Then, dial the
number from the keypad.
5. When you finish dialing, turn the tester over.
You can now use the speaker and microphone as a standard handset.
Note
If the volume of the speaker needs to be adjusted, see “Adjusting the
Volume of the Speaker”, earlier in this chapter.