POTS Testing and Fault Location
POTS Auto-Test
4
4-3
3. If desired, supply a value for each generic setup parameter.
Note
Table 3-1 describes the generic setup parameters. If you need
instructions for changing their values, see “Editing the Setup for a
Test” in Chapter 3.
4. Select the tests that you want to include in the Auto-Test. For each test, do
the following:
a) Press F or H to select the test. Then, press A(
Edit).
b) Press F or H to select
Y if you want to include the test or N if you
do not want to include the test.
c) Press L to save your selection.
Note
To restore the factory default values of the setup parameters, press
D(
Restore Defaults).
To change the setup for any of the individual tests, see “Editing the
Setup for a Test” in Chapter 3. Individual test default settings are for
POTS service qualification.
There is a second screen of setups for the POTS Auto-Test, accessible by
pressing C (
More). Table 4-1 lists the tests you can include in the POTS Auto-
Test, plus other setup parameters on the second setups screen.