EasyManua.ls Logo

Fluke 990DSL - Page 144

Fluke 990DSL
242 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
990DSL
Users Guide
5-6
Table 5-1. Service Types for Qualification (continued)
Service Type Qualification Criteria
T1 • Param. results vs. T1 Pass Thresholds
• 772 kHz (Nyquist) Loss & WB Long. Bal.
Custom • Param. results vs. User-entered Thresholds
• WB / BB Loss & WB Long. Balance @ User-
entered Frequency (Nyquist)
All (default) • Param. results vs. Tightest Pass Thresholds
of all above Services except ADSL2+ &
VDSL
• WB / BB Loss & WB Long. Balance @
Nyquist Frequencies of all above Services
4. From Setup Screen 1, select the
Loss Pass / Fail Thresholds field.
Choose one of the following options:
a)
Predefined Thresholds (default) – These Pass / Fail thresholds are
factory-predefined for the Service Type chosen, with unique values
for each test.
OR
b)
Custom Thresholds – This selection uses existing Pass / Fail
thresholds that you have entered in the Setups menu for each of the
individual tests in the sequence, allowing the qualification of a new or
different Service Type.
5. From Setup Screen 1, enter appropriate selections for Cable Type, Cable
Gauge
, and Cable Temperature.

Table of Contents