202 Upgrade and Maintenance Manual TX1310 M3
System board and components
Ê Remove the protective cover from the CPU socket of the new system board,
see section "Removing the protective cover" on page 151.
Ê Remove the CPU from the defective system board, see section "Removing
the CPU" on page 135.
Ê Confirm that the CPU model number printed on the top of the CPU fits with
the requirements.
Ê Install the CPU on the new system board, see section "Installing the CPU"
on page 138.
Ê Fit the protective plastic cover of the new system board onto the socket of
the defective system board which will to be returned.
I Returned system boards without this cover will probably have to be
scrapped.
15.4.4 Concluding steps
Ê Connect all cables to the system board. For the cable plans, please refer to
section "Cabling plans" on page 206.
Ê If applicable, "Installing the TPM" on page 186.
Ê Install the memory modules, see section "Installing a memory module" on
page 124.
I Make sure that you reinstall each memory module in the slot it was
located before the replacement.
Ê Install the heat sink, see section "Installing the heat sink" on page 143.
Ê Install all expansion cards, see section "Expansion cards" on page 113.
I Make sure that you reinstall each card in the slot it was located before
the replacement.
Ê Install the air deflector, see section "Installing the air deflector" on page 59.
Ê "Reassembling" on page 51
Ê Connect all external cables.
Ê "Connecting the power cord" on page 56