232 Upgrade and Maintenance Manual TX1310 M3
Appendix
17.4 Minimum startup configuration
If the server does not start up or other problems occur, it may be necessary to
take the system down to its most basic configuration in order to isolate the
defective component.
The minimum startup configuration consists of the following components and
cables:
Ê "Shutting down the server" on page 44
Ê "Disconnecting the power cord" on page 45
Ê Take the system down to its minimum startup configuration.
Ê "Connecting the power cord" on page 56
Ê Connect a display to the server.
Ê "Switching on the server" on page 57
Field Replaceable Units (FRU)
Component Notes
System board no TPM or expansion cards installed
1 CPU with heat sink installed in CPU1
1 CPU fan
1 memory module installed in slot CHA1
1 PSU installed in PSU1
Table 7: Minimum startup configuration - components
Cable Notes
Power cable