88 Upgrade and Maintenance Manual TX1310 M3
Hard disk drives (HDDs)
7.3 Removing 3.5-inch HDDs
7.3.1 Preliminary steps
Ê If the HDD module to be removed is combined into a RAID array, please
proceed as follows:
In order to permanently remove an operational HDD module that is part of a
RAID array from the server, you first need to delete the array using
ServerView RAID Manager.
Upgrade and Repair Unit
(URU)
Hardware: 5 minutes
Tools: tool-less
RAID level Procedure
RAID 0
Only remove an HDD module combined in a RAID 0 array if
defective.
V CAUTION!
Removing an operational HDD module will result
in data loss!
RAID 1
Removing an HDD module from a RAID 1 array will not
result in data loss.
However, the removed drive needs to be replaced
immediately by an HDD module of the same or larger
capacity.
I After replacing the HDD module, RAID rebuild will
be performed as a background process, see
section "Performing a RAID array rebuild" on
page 71.