Technical Manual
October 1, 1995 18-006/081-04 GB
31
99 - THEN output As 95 - 98 but will also send alarm message to THOR intrusion. This soft
type has to be used if an alarm message must be send to the THOR
intrusion system, f.ex. Door Forced. In THOR Intrusion it is received as
address 30 + the reader address and can in the Intrusion be defined
freely as an input soft type from the Intrusion list.
This soft type can, as the only one, be programmed to an non-existing S-
ART address without having a sabotage message from the address. If
the soft type is programmed to an S-ART output to control a relay, one of
the two S-ART inputs must be used with an input soft type.