5 Installation and commissioning
118
HSD S.p.A. © - h0104k01a.fm120718
5.9 Programming the inverter
Refer to paragraph
3.5 “Features and performance” for information on how to parameterise
the inverter.
The maximum voltage set on the inverter must correspond to the rated value indicated on the
motor rating plate.
The set frequency value at which the voltage becomes maximum (rated frequency) must
correspond to the rated value indicated on the motor rating plate.
The maximum speed set on the inverter must correspond to the value indicated on the motor
rating plate.
The maximum continuous current set on the inverter must correspond to the rated current
value indicated on the motor rating plate.
Contact the manufacturer if it is considered necessary to check the other parameters of the
inverter.