Step 2 Configure a master NTP clock on Switch A and enable NTP authentication.
# On Switch A, set the clock as a master NTP clock with stratum being 2.
<SwitchA> system-view
[SwitchA] ntp-service refclock-master 2
# Enable NTP authentication on Switch A, configure the authentication key, and declare the key
to be reliable.
[SwitchA] ntp-service authentication enable
[SwitchA] ntp-service authentication-keyid 42 authentication-mode md5 Hello
[SwitchA] ntp-service reliable authentication-keyid 42
The authentication keys configured on the server and the client must be the same.
Step 3 Configure Switch B as the NTP server and enable the NTP authentication.
# Enable NTP authentication on Switch B, configure the authentication key, and declare the key
to be reliable.
<SwitchB> system-view
[SwitchB] ntp-service authentication enable
[SwitchB] ntp-service authentication-keyid 42 authentication-mode md5 Hello
[SwitchB] ntp-service reliable authentication-keyid 42
# # Configure Switch A to be the NTP server of Switch B and use the authentication key.
[SwitchB] ntp-service unicast-server 2.2.2.2 authentication-keyid 42
Step 4 Specify the NTP server for Switch C.
# Configure Switch B as the NTP server of Switch C.
<SwitchC> system-view
[SwitchC] ntp-service authentication enable
[SwitchC] ntp-service authentication-keyid 42 authentication-mode md5 Hello
[SwitchC] ntp-service reliable authentication-keyid 42
[SwitchC] ntp-service unicast-server 10.0.0.1 authentication-keyid 42
Step 5 Specify the NTP server for Switch D.
# Configure Switch B as the NTP server of Switch D.
<SwitchD> system-view
[SwitchD] ntp-service authentication enable
[SwitchD] ntp-service authentication-keyid 42 authentication-mode md5 Hello
[SwitchD] ntp-service reliable authentication-keyid 42
[SwitchD] ntp-service unicast-server 10.0.0.1 authentication-keyid 42
Step 6 Verify the configuration.
After the configurations, Switch B can synchronize its clock with the clock of Switch A.
Check the NTP status of Switch B, and you can view that the status of the clock is synchronized.
This means that the synchronization is complete. The stratum of the clock of Switch B is 3, one
stratum lower than the clock stratum of Switch A.
[SwitchB] display ntp-service status
clock status: synchronized
clock stratum: 3
reference clock ID: 2.2.2.2
nominal frequency: 60.0002 Hz
actual frequency: 60.0002 Hz
clock precision: 2^18
clock offset: 3.8128 ms
root delay: 31.26 ms
root dispersion: 74.20 ms
Quidway S5700 Series Ethernet Switches
Configuration Guide - Network Management 4 NTP Configuration
Issue 01 (2011-10-26) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
230

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei Quidway S5700 Series and is the answer not in the manual?

Huawei Quidway S5700 Series Specifications

General IconGeneral
CategorySwitch
Operating Temperature0°C to 45°C
Relative Humidity5% to 95% (non-condensing)
SeriesQuidway S5700
Forwarding PerformanceUp to 96 Mpps
Ports24 or 48 x 10/100/1000Base-T ports
Power SupplyAC or DC
Storage Temperature-40°C to 70°C
Fixed GE Ports24 or 48
Uplink Ports4 x GE SFP ports
Routing ProtocolsRIP, OSPF, BGP
ManagementSNMP, RMON, CLI, Web
VLAN4094 VLANs
PoEOptional

Related product manuals