peer dispersion: 34.30 ms
reference time: 11:55:56.833 UTC Mar 2 2006(C7B15BCC.D5604189)
After the configurations, Switch C can synchronize its clock with the clock of Switch B.
Check the NTP status of Switch C, and you can view that the status of the clock is synchronized.
This means that the synchronization is complete. The stratum of the clock of Switch C is 4, one
stratum lower than the clock stratum of Switch B.
[SwitchC] display ntp-service status
clock status: synchronized
clock stratum: 4
reference clock ID: 10.0.0.1
nominal frequency: 60.0002 Hz
actual frequency: 60.0002 Hz
clock precision: 2^18
clock offset: 3.8128 ms
root delay: 31.26 ms
root dispersion: 74.20 ms
peer dispersion: 34.30 ms
reference time: 11:55:56.833 UTC Mar 2 2006(C7B15BCC.D5604189)
Check the NTP status of Switch D, and you can see that the status of the clock is synchronized.
This means that the synchronization is complete. The stratum of the clock of Switch C is 4, one
stratum lower than the clock stratum of Switch B.
[SwitchD] display ntp-service status
clock status: synchronized
clock stratum: 4
reference clock ID: 10.0.0.1
nominal frequency: 60.0002 Hz
actual frequency: 60.0002 Hz
clock precision: 2^18
clock offset: 3.8128 ms
root delay: 31.26 ms
root dispersion: 74.20 ms
peer dispersion: 34.30 ms
reference time: 11:55:56.833 UTC Mar 2 2006(C7B15BCC.D5604189)
Check the NTP status of Switch A.
[SwitchA] display ntp-service status
clock status: synchronized
clock stratum: 2
reference clock ID: LOCAL(0)
nominal frequency: 60.0002 Hz
actual frequency: 60.0002 Hz
clock precision: 2^18
clock offset: 0.0000 ms
root delay: 0.00 ms
root dispersion: 26.50 ms
peer dispersion: 10.00 ms
reference time: 12:01:48.377 UTC Mar 2 2006(C7B15D2C.60A15981)
----End
Configuration Files
l Configuration file of Switch A
#
sysname SwitchA
#
vlan batch 100
#
interface Vlanif100
ip address 2.2.2.2 255.255.255.0
#
Quidway S5700 Series Ethernet Switches
Configuration Guide - Network Management 4 NTP Configuration
Issue 01 (2011-10-26) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
231

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei Quidway S5700 Series and is the answer not in the manual?

Huawei Quidway S5700 Series Specifications

General IconGeneral
CategorySwitch
Operating Temperature0°C to 45°C
Relative Humidity5% to 95% (non-condensing)
SeriesQuidway S5700
Forwarding PerformanceUp to 96 Mpps
Ports24 or 48 x 10/100/1000Base-T ports
Power SupplyAC or DC
Storage Temperature-40°C to 70°C
Fixed GE Ports24 or 48
Uplink Ports4 x GE SFP ports
Routing ProtocolsRIP, OSPF, BGP
ManagementSNMP, RMON, CLI, Web