EasyManuals Logo
Home>IBM>Storage>TS2900

IBM TS2900 User Manual

IBM TS2900
286 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #223 background imageLoading...
Page #223 background image
Drive error codes
Table 33. Drive error codes
Code (H) Description Panel indication Action Required
0200 Invalid data sent to drive.
NAK detected.
CHK 0200
1. Reseat all cables. See “Reseating
cables” on page 137.
2. Cycle the power supply and try
again.
v If the problem is corrected, run
Library Verify before normal
library operations resumes.
v If the problem persists, see
“Contacting IBM technical
support” on page 139.
0201 Timeout error occurred
while drive is waiting for
response.
CHK 0201
0203 Drive disconnected. CHK 0203
0205 Drive busy. CHK 0205
0206 Command could not be
executed because drive is
not mounted.
CHK 0206
020E Drive error detected. CHK 020E
020F Unsupported drive
detected.
CHK 020F
0222 Media could not be
ejected because drive is
in Prevent Medium
Removal state.
CHK 0222
1. Release the drive Prevent Medium
Removal state from the host.
2. Reseat all cables. See “Reseating
cables” on page 137.
3. Cycle the power supply and try
again.
v If the problem is corrected, run
Library Verify before normal
library operations resumes.
v If the problem persists, see
“Contacting IBM technical
support” on page 139.
Web User Interface error messages
Table 34. Web user error messages
Title Message Issuing Panel
Error Users full. User Access
You cannot remove yourself. User Access
Appendix B. Error codes 197