Table 39. Library sense data (continued)
Sense Key ASC ASCQ Description
Aborted Command (0B) 41 nn LDI command failure**
* This code is preserved only in the library log when “FID” or “ATTN DRV” message is received from the tape
drive. This code is not reported to the host server.
** This code is preserved only in the library log. This code is not reported to the host server.
Tape drive sense data
Table 40. Ultrium Tape drive sense data
Byte
Bit Address or Name
7 6 5 4 3 2 1 0
0 Valid
Address Bit
Error Code
1 Segment Number x'00'
2 Filemark EOM
(End of
medium)
ILI
(Incorrect
length
indicator
Reserved Sense Key
See “Sense Key definitions” on page 207.
3 Information byte (most significant byte)
4-5 Information bytes
6 Information byte (least significant byte)
7 Additional sense length
8-11 Command specific information bytes
12-13 For Ultrium Tape drive sense data for Bytes 12 and 13, see Table 41 on page 210.
14 Field Replaceable Unit (FRU) ID
15 SKSV C/D Reserved BPV
(Bit pointer
valid)
Bit pointer
16-17 SKSV =0: First Error Fault Symptom Code (FSC); SKSV = 1: Field Pointer
18-19 First Error Flag Data
20 Reserved (0)
21 CLN Reserved Reserved VolValid
22-28 Volume Label
29 Current Wrap
30-33 Relative LPOS
34 SCSI Address
35 Frame number Drive number
36-39 Port Identifier (Relative Target Port Address) Reporting Sense
This is the hashed SAS address of the drive port (for example, F32A94) with byte 36 being reserved.
Appendix D. Sense data 209