Table 16. Default library configuration settings (continued)
Configuration Item Default Setting
Primary EKM TCP port number 3801
Primary EKM SSL port number 443
Secondary EKM server address 0.0.0.0
Secondary EKM TCP port number 3801
Secondary EKM SSL port number 443
Advanced encryption settings (None)
DATE and TIME
NTP server Disabled
NTP server address 0.0.0.0
Time zone (GMT) +00:00
Date (MM/DD/YYYY) 01/08/2008
Auto adjustment by PC Every 1 minute
NOTIFICATIONS
SMTP (mail) settings
Mail server address 0.0.0.0
Mail event Error events enabled
SNMP (trap) settings
Community Public
Trap event Error events enabled
SNMPv3 engine ID (Set by library firmware)
Static library network settings must be entered with the Operator Panel before the library can be accessed
remotely with the Web User Interface. If your system is serviced by a Dynamic Host Configuration
Protocol (DHCP) server, the network parameters are automatically set. Once remote access is established,
you can complete the configuration of your library remotely.
If you choose to use the Operator Panel to configure your library, go to “Configuring your library with
the Operator Panel” on page 54.
Configuring your library with the Web User Interface
If you choose to use the Web User Interface to configure your library, first enter your library network
settings with the Operator Panel (see “Configuring network settings” on page 71).
To configure your library with the Web User Interface:
1. “Logging in to the Web User Interface” on page 38
2. “Checking firmware level” on page 38
3. “Configuring library settings” on page 39
4. “Configuring network settings” on page 41
5. “Configuring date and time settings” on page 42
6. “Configuring encryption settings” on page 44
7. “Configuring email notifications” on page 47
8. “Configuring trap notifications” on page 48
9. “Managing user access” on page 50
Installation and configuration 37