Release History Table DescriptionRelease
Starting in Junos OS Release 14.1X53, a Raw Report can be generated from
the log messages being loaded in the Events Detail table.
14.1X53
Starting in Junos OS Release 14.1X53, a Formatted Report can be generated
from event log messages being loaded in an Events Detail table.
14.1X53
Related
Documentation
Checking Active Alarms with the J-Web Interface on page 186•
• Understanding Alarm Types and Severity Levels on EX Series Switches on page 30
Monitoring Chassis Information
Purpose NOTE: This topic applies only to the J-Web Application package.
Use the monitoring functionality to view chassis properties such as general switch
information, temperature and fan status, and resource information for the EX Series
switch.
Action To view chassis properties in the J-Web interface, select Monitor > System View > Chassis
Information. For an EX8200 Virtual Chassis configuration, select the Virtual Chassis
member from the list.
To view chassis properties in the CLI, enter the following commands:
• show chassis environment
• show chassis fpc
• show chassis hardware
Meaning Table 87 on page 192 gives information about the key output fields for chassis information.
NOTE: For an EX2200, EX2200-C, EX3200,or EX4500 switchor an EX4200,
EX4300, or EX4550 standalone switch, the FPC slot number refers to the
switch itself and is always 0. In a Virtual Chassis configuration, the FPC slot
number refers to the member ID.
191Copyright © 2017, Juniper Networks, Inc.
Chapter 16: Monitoring Tasks