10-14 Remote Operations Model 2700 Multimeter/Switch System User’s Manual
Long-form and short-form versions
An SCPI command word can be sent in its long-form or short-form version. The command
subsystem tables in
Section 15 provide the long-form version. However, the short-form
version is indicated by upper case characters. Examples:
SYSTem:PRESet long-form
SYST:PRES short-form
SYSTem:PRES long-form and short-form combination
Note that each command word must be in long-form or short-form, and not something in
between. For example, SYSTe:PRESe is illegal and will generate an error. The command
will not be executed.
Short-form rules
Use the following rules to determine the short-form version of any SCPI command:
If the length of the command word is four letters or less, no short form version
exists. Example:
:auto = :auto
These rules apply to command words that exceed four letters:
If the fourth letter of the command word is a vowel (including “y”), delete it and all
the letters after it. Example
immediate = imm
If the fourth letter of the command word is a consonant, retain it but drop all the
letters after it. Example:
format = form
If the command contains a question mark (?; query) or a non-optional number
included in the command word, you must include it in the short-form version.
Example:
:delay? = :del?
Command words or characters that are enclosed in brackets ([ ]) are optional and
need not be included in the program message.
NOTE For fastest response to commands, always use short forms.

Table of Contents

Other manuals for Keithley 2700

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keithley 2700 and is the answer not in the manual?

Keithley 2700 Specifications

General IconGeneral
TypeDigital Multimeter
Measurement FunctionsDC Voltage, AC Voltage, DC Current, AC Current, Resistance, Frequency, Temperature
DC Voltage Range100 mV to 1000 V
AC Voltage Range100 mV to 750 V
Frequency Range3 Hz to 500 kHz
Temperature Range-200°C to +1372°C
DisplayVacuum Fluorescent Display
ConnectivityIEEE-488, RS-232
Channels10
Power Supply100V to 240V AC, 45Hz to 66Hz
DC Current Range10 µA to 3 A
AC Current Range10 µA to 3 A
Temperature MeasurementThermocouple, RTD