15-2 SCPI Reference Tables Model 2700 Multimeter/Switch System User’s Manual
Reference tables
Table 15-1 through Table 15-10 summarize the commands to operate the Model 2700 and
Model 7700 switching module.
NOTE The commands listed in the following tables pertain to operation of the
Model
2700 and the Model 7700 switching module. For commands that are
unique to operation of other switching modules, refer to the packing list
provided with each switch module.
Table 15-1 — CALCulate command summary
Table 15-2 — DISPlay command summary
Table 15-3 — FORMat command summary
Table 15-4 — ROUTe command summary
Table 15-5 — SENSe command summary
Table 15-6 — STATus command summary
Table 15-7 — SYSTem command summary
Table 15-8 — TRACe command summary
Table 15-9 — Trigger command summary
Table 15-10 — UNIT command summary
General notes:
Brackets ([ ]) are used to denote optional character sets. These optional characters
do not have to be included in the program message. Do not use brackets in the
program message.
Angle brackets (< >) are used to indicate parameter type. Do not use angle brackets
in the program message.
The Boolean parameter (<b>) is used to enable or disable an instrument operation.
1 or ON enables the operation, and 0 or OFF disables the operation.
Upper case characters indicate the short-form version for each command word.
Default Parameter — Listed parameters are both the *RST and SYSTem:PRESet
defaults, unless noted otherwise. Parameter notes are located at the end of each
table.
Ref — The reference column indicates where to find detailed information on the
command(s).
SCPI — A checkmark () indicates that the command and its parameters are SCPI
confirmed. An unmarked command indicates that it is an SCPI command, but does
not conform to the SCPI standard set of commands. It is not a recognized
command by the SCPI consortium. SCPI confirmed commands that use one or
more non-SCPI parameters are explained by notes.

Table of Contents

Other manuals for Keithley 2700

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keithley 2700 and is the answer not in the manual?

Keithley 2700 Specifications

General IconGeneral
TypeDigital Multimeter
Measurement FunctionsDC Voltage, AC Voltage, DC Current, AC Current, Resistance, Frequency, Temperature
DC Voltage Range100 mV to 1000 V
AC Voltage Range100 mV to 750 V
Frequency Range3 Hz to 500 kHz
Temperature Range-200°C to +1372°C
DisplayVacuum Fluorescent Display
ConnectivityIEEE-488, RS-232
Channels10
Power Supply100V to 240V AC, 45Hz to 66Hz
DC Current Range10 µA to 3 A
AC Current Range10 µA to 3 A
Temperature MeasurementThermocouple, RTD