EasyManuals Logo

Keysight Technologies X Series Service Guide

Keysight Technologies X Series
671 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #373 background imageLoading...
Page #373 background image
40 MHz BW IF SYSTEM BLOCK DIAGRAM
40 MHz BW IF SYSTEM
BLOCK DIAGRAM
blocke40_if40
A2 ANALOG IF
J100
J820
IF COMB CAL
HI/
LO
25 MHz
12 MHz
to mux
to mux
J300
From
A15J900
322.5 MHz
IN
22.5 MHz
LC
XTAL
25 MHz
22.5 MHz
22.5 MHz
+4 dBm
22.5 MHz
IF
P/O
W43
ribbon cable
P/O
W2
ribbon cable
J601
STEP
GAIN
J820
TRIG
12 MHz
300 kHz
300 kHz/800 kHz
9 kHz/60 kHz
+13 dB
From A16J711
LEVEL
To mux
TRIG
GAIN
BURST CARRIER TRIGGER
+13 dB
1 dB
Step
300 MHz LO
+10 dBm
22.5 MHz
COMB
THERMOMETER
+
-
A3 DIGITAL IF
J18
J15
J19
J14
ST GT
250 MHz
IF
From A15J705
From A15J901
To A13J6
From A15J926
From A16J706
From A15J716
100 MHz
REF
J9
J10
WB_ALIGN_DATA
DAC
DAC
DITHER
40 MHz BW
250 MHz CF
200 MHz 200 MHz
6 dB
200 MHz
Notch
Lockn
clock
125 MHz
T2
ILB Module
TEMPERATURE
SENSOR
FELDSPAR
DSP
FELDSPAR_CLK
PECL -> ECL
TRIGGER 2 IN
(BNC)
TRIGGER 1 IN
(BNC)
ADC1 Clk
SYS Clk
FELDSPAR Clk
IF 10M REF
10MHz
OUT
(BNC)
AFPGA_10 MHz
AFPGA_100 MHz
CA6/AUDIO
(P1-C6)
ECAL IN
Noise Source
Drive +28V
(BNC)
N.C.
IF_10M_REF
to Reference Bd
AFPGA_100MHz
Diag_to_adc
TRIG_1
TRIG_2
Trig2_Lev
Trig1_Lev
LINE_TRIG
AIF_TRIG
INT_SWP
SETTLED
COMB_1
COMB_2
LOCKn
STEP
CAL
DRIVE
J11
J4
J5
J13
J7
J6
J8
J16
ADC2
(12 bit)
ADC1
(16 bit)
J17
ALIGN OUT
X2
Memory
Controller
Recon (15.0)
ADC2p/n_CLK
ADC2
ADC1
ADC1
Clk
ADC2
Clk
Capture
Memory
RECONSTRUCTION
Noise
Source
T2
Rx
Module
Recon
Gain DAC
Clock
Distribution
INTERPOLATOR
CAL TRIGGER
DAC
ANALOG FPGA
EXT_TRIG_1
EXT_TRIG_2
INTERP_CAL_TRIG
GATE_ARM
TRIG_1
GATE_TRIG
TRIG_2
SWEEP_ARM
LINE_TRIG
AIF_TRIG
SWEEP_TRIG
INT_SWP
SETTLED
SETTLED
COMB_1
ASG/COMB GEN
COMB_2
T2
(TRIGGER MODULE)
TRIG_OUT1
ILB Bus PCI Bus
TRIG_OUT1
TRIGGER
BUFFER
J20
P/O W2 Ribbon Cable
EXT SYNC
TRIG_OUT2
TRIG_OUT2
INT_SWP
INT_SWP
TSTRETCH
PART_SAMP
PULSE
STRETCHER
TRIGGER1
OUT
(BNC)
TRIGGER2
OUT
(BNC)
SYNC
(BNC)
}
SNS
Noise Source
Digital Bus
Analog Out
(BNC)
W37
W14
W41
W38
W40
W50
W42
W43
5
5
3
4
3
W54
(5) Connection depends upon option and serial prefix.
Serial Prefix Option Cable
<MY/SG/US5648 B40, DP2, or MPB W40
>MY/SG/US5648 B40, DP2, or MPB W50
(4) This cable only used on analyzers with serial prefix < MY/SG/US5648
(3) W42 is used on serial prefix < MY/SG/US5648 ;
W54 is used on serial prefix > MY/SG/US5648
FOOTNOTES
January 10, 2017

Table of Contents

Other manuals for Keysight Technologies X Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight Technologies X Series and is the answer not in the manual?

Keysight Technologies X Series Specifications

General IconGeneral
BrandKeysight Technologies
ModelX Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals