EasyManua.ls Logo

Keysight Technologies X Series - -100 to -199, Command Errors

Keysight Technologies X Series
671 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
112 Keysight N9010A EXA Service Guide
Instrument Messages
-100 to -199, Command Errors
-100 to -199, Command Errors
Err# Message Verbose/Correction Information
-100 Command error There is a problem with the command. The exact problem cannot be
specifically identified.
-101 Invalid character An invalid character was found in part of the command.
-102 Syntax error An unrecognized command or data type was found, for example a
string was received for a command that doesn’t accept strings.
-103 Invalid separator The command was supposed to contain a separator but we found an
illegal character. For example, the semicolon was omitted after a
command string.
-104 Data type error We found a data type different then what was expected. For example,
numeric or string data was expected, but block data was found.
-105 GET not allowed A Group Execute Trigger was received within a program message.
-108 Parameter not allowed More parameters were received than were expected for the command.
For example, the *ESE common command only accepts one
parameter, so sending *ESE 0,1 is not allowed.
-109 Missing parameter Fewer parameters were received than required for this command.
-110 Command header error This is a general error that is generated when a problem is found in a
command header, but we cant tell more specifically what the problem
is
-111 Header separator error We found an illegal character in a command where we expected to
find a separator.
-112 Program mnemonic too long The command contains a keyword that is more than twelve characters.
-113 Undefined header The command meets the SCPI syntax requirements, but is not valid in
the current measurement environment.
-114 Header suffix out of range The value of a numeric suffix that is attached to a program mnemonic
makes the header invalid. (A suffix is usually units, like Hz or DB.)
-115 Unexpected number of
parameters
The number of parameters received does not correspond to the
number of parameters expected.
-120 Numeric data error An error was found in a data element that appears to be numeric. The
exact problem cannot be specifically identified.
-121 Invalid character in number A character was found that is not valid for the data type. For example,
an alpha in a decimal numeric or a “9” in octal data.
-123 Exponent too large The magnitude of an exponent was greater than 32000.
-124 Too many digits The mantissa of a decimal-numeric contained more than 255 digits,
excluding leading zeros.