206 L EDS94ARNExxxx EN 2.3 - 06/2014
0x006a0006 6946822 IdleTask: Overflow Fault -
0x00790000
7929856 Incorrect device command transfer System fault -
0x00680012
6815762 Incorrect memory module System fault -
0x00680013
6815763 Incorrect safety module System fault -
0x00770011
7798801 Inside the device: Fan is defect Fault C00611
0x0077000b 7798795 Inside the device: Thermal detector is defect Fault C00588
0x007b0034 8060980 Internal communication error (DMA) System fault -
0x007b0014
8060948 Internal communication error (host MCTRL) System fault -
0x007b0036
8060982 Internal communication error (MCTRL host) System fault -
0x00690009
6881289 Internal error (event mechanism) System fault -
0x0069000a
6881290 Internal error (event mechanism) System fault -
0x0069000d
6881293 Internal error (file system lifetime) Warning -
0x00690002
6881282 Internal error (LDS instance data) System fault -
0x00690003
6881283 Internal error (LDS tasks) System fault -
0x00690001
6881281 Internal error (memory area - logbook) System fault -
0x00690006
6881286 Internal error (message memory) System fault -
0x00690007
6881287 Internal error (message queue) System fault -
0x00690008
6881288 Internal error (name data base) System fault -
0x0069000b
6881291 Internal error (semaphores) System fault -
0x0069000c
6881292 Internal error (semaphores) System fault -
0x00690004
6881284 Internal error (storage blocks) System fault -
0x00690005
6881285 Internal error (task queue) System fault -
0x00910004
9502724 Internal error: See C00180 System fault -
0x00910005
9502725 Internal error: See C00180 System fault -
0x00910006
9502726 Internal error: See C00180 System fault -
0x00910008
9502728 Internal error: See C00180 Fault -
0x00910009
9502729 Internal error: See C00180 Fault -
0x00900001
9437185 Lenze setting loaded Information -
0x00900004
9437188 Loading of Lenze setting failed Fault -
0x00650000
6619136 Logbook: Overflow Information -
0x00650001
6619137 Logbook: Reset (read error) Information -
0x00650002
6619138 Logbook: Reset (version error) Information -
0x007b0049
8061001 Mains not connected Trouble -
0x007b0045
8060997 Mains voltage 10% too high Warning -
0x007b0043
8060995 Mains voltage 10% too low Warning -
0x007b0046
8060998 Mains voltage 15% too high Fault -
0x007b0044
8060996 Mains voltage 15% too low Fault -
0x00910001
9502721 Mains voltage is switched off Information -
0x00910000
9502720 Mains voltage is switched on Information -
0x00680017
6815767 Memory module has been changed Information or warning locked if
the hardware type has changed
as well.
-
0x00680006
6815750 Memory module has been removed System fault -
0x00680002
6815746 Memory module is defect or missing Fault -
0x0068000c
6815756 Memory module is defect or missing System fault -
0x00650003
6619139 Memory module is missing Information -
0x0068001c
6815772 Memory module: Faulty file system Fault -
0x007c0000
8126464 Memory module: File system has been formatted Information -
0x007c0001
8126465 Memory module: File system has been restored Information -
0x008c0017
9175063 MXI1: CAN module is missing or incompatible Fault -
0x008c0011
9175057 MXI1: Ethernet module is missing or incompatible Fault -
0x008c0015
9175061 MXI1: ICM module is missing or incompatible Fault -
Error number Error message Response Adjustable in