Diagnostic aids 3-3
4024-XXX
4. Select the actual test to perform.
Each of the tests categories includes the individual sensors that can be manually actuated and the display
shows Open or Closed.
Cover and Door
Cover F bridge top
Door G fin front
Surface H fin eject
Bin Level
Fin upper bin full
Stacker bin level1
Stacker bin level2
Stacker bin upper limit
Stacker bin no media
Stacker bin level encod
Media Path1
Fuser exit
Bridge media ent
Bridge media exit
Fin media ent
Buffer path
Upper media exit
Lower media exit
Compiler media in
Media Path2
Diverter gate
Front tamper hp
Rear tamper hp
Eject clamp hp
Media eject shaft hp
Punch and Staple
Punch side reg1
Punch side reg2
Punch box set
Punch waste full
Low staple
Punch carriage shift hp
Punch unit hp
Stapler carriage shift hp
Punch cam front
Punch hole select
Press Back () or Stop ( ) to exit the test.
EXIT DIAGNOSTICS
This selection exits Diagnostics mode and Resetting the Printer displays. The printer performs a POR
and the printer returns to normal mode.

Table of Contents