4-98 Finisher Service Manual
4024-XXX
Sensor (finisher media entrance) removal
1. Open the front door assembly.
2. Remove the rear upper cover. See “Rear upper cover removal” on page 4-24.
3. Remove the top cover. See “Top cover removal on page 4-19.
4. Remove the left lower cover. See “Left lower cover removal” on page 4-28.
5. Remove the left upper cover. See “Left upper cover removal” on page 4-29.
6. Disconnect the connector from the sensor (finisher media entrance) (A).
7. Release the harness from the clamp.
8. Remove the screw securing the bracket (B) to the media entrance pinch guide assembly (C).
9. Release the hooks securing the sensor (finisher media entrance) (A) to the bracket (B).
10. Remove the sensor (finisher media entrance) (A).
A
B
C
Left
Clamp
Connector