Repair information 4-17
4024-XXX
Sensor (bridge unit media exit) removal
1. Remove the bridge unit assembly. See “Bridge unit assembly removal” on page 4-2.
2. Place the bridge unit upside down.
3. Remove the screw securing the bracket (A) to the bridge unit (B).
4. Disconnect the connector from the sensor (bridge unit media exit) (C).
5. Release the hooks securing the sensor (bridge unit media exit) (C) to the bracket (A).
6. Remove the sensor (bridge unit media exit) (C).