Diagnostic information 2-17
4024-XXX
7 Perform a test print.
Does the error still occur?
Replace the
bridge unit
interface card
assembly. Go to
“Bridge unit
interface card
assembly
removal” on
page 4-117.
Go to step 8.
Problem solved.
8 Perform a test print.
Does the error still occur?
Replace the
finisher controller
card assembly.
Go to Finisher
controller card
assembly
removal” on
page 4-118.
Problem solved.