Diagnostic aids 3-37
7541-03x
Photoconductor Clean/Erase
After each plane of color has been transferred to the transfer belt from the photoconductors, a cleaning blade
scrapes the remaining toner from the surface of each photoconductor. This is the clean/erase process.
Now the photoconductor surface is prepared to begin the EP cycle once again. This cleaning/erasing cycle
happens after each plane of color is transferred to the transfer belt.
Cleaning
blade