Diagnostic information 2-53
7541-03x
146.04 Tray 4 error
Note: This is the second expansion tray.
11
Replace the paper full sensor cable. Did this fix the
problem?
Problem solved. Go to step 12.
12
Replace the paper full sensor. Did this fix the issue? Problem solved. Go to step 13.
13
Replace the expansion paper feeder controller board.
Did this fix the issue?
Problem solved. Go to step 14.
14
Check pins 6 and 7 on CN13 of the printer controller
board for + 24V. Is the voltage correct?
Contact your
second level
support.
Replace the
printer controller
board
Step Action and questions Yes No
1 Check CN 121 on the first expansion paper feeder’s
expansion feeder controller board for proper
connectivity. Is it properly connected?
Go to step 3. Go to step 2.
2
Reconnect the cable to CN 121.Did this fix the
problem?
Problem
resolved.
Go to step 3.
3
Check CN 120 on the second expansion paper
feeder’s expansion feeder controller board for proper
connectivity. Is it properly connected?
Go to step 5. Go to step 4.
4
Reconnect the cable to CN 120.Did this fix the
problem?
Problem
resolved.
Go to step 5.
5
Check CN 103 on the second expansion paper
feeder’s expansion feeder controller board for proper
connectivity. Is it properly connected?
Go to step 7. Go to step 6.
6
Reconnect the cable to CN 103.Did this fix the
problem?
Problem
resolved.
Go to step 7.
7
Replace the paper full sensor. Does this fix the
problem?
Problem
resolved.
Go to step 8.
8
Replace the expansion paper feeder controller board.
Does this fix the problem?
Problem
resolved.
Contact you
second level
support.
Step Action and questions Yes No