Repair information 4-173
7541-03x
Duplex timing belt removal
1. Remove the duplex clutch.See “Duplex clutch removal” on page 4-172.
2. Remove the timing belts.
Duplex exit / MPF sensor removal
1. Remove the duplex unit. See “Duplex removal” on page 4-63.
2. Remove the duplex exit / MPF sensor actuator.
3. Disconnect the sensor harness.
4. Pinch the tabs (C) that secure the sensor to the duplex unit.
C