4. Parameters
4-29
Parameter Unit Initial
Details
Applic
ation
mode
Code Name Minimum Maximum
St-19
Internal
temperature
[]
0
Displays the internal temperature sensor value.
PST
Room
temperature
-40 200
St-20
Rated motor
speed
[RPM] 0
Displays the rated speed of the currently
installed motor.
PST
Rated RPM 0 10000
St-21
Maximum motor
speed
[RPM] 0
Displays the maximum speed of the currently
installed motor.
PST
Maximum RPM 0 10000
St-22
Rated motor
current
[A] 0.00
Displays the rated current of the currently
installed motor.
PST
Rated current 0.00 655.35
St-23
U phase current
offset
[mA] 0
Displays the U phase current offset.
PST
U Phase current
offset
-200 200
St-24
V phase current
offset
[mA] 0
Displays the V phase current offset.
PST
V phase current
offset
-200 200
St-25
Program version - -
Displays the version of the currently installed
program.
(Details: Refer to “4.3.7 Software Version
Display.”)
PST
Software version - -
St-26
FPGA Version - -
Displays the version of the currently installed
FPGA version.
PST
FPGA Version - -
St-27
Analog Torque
Command
% 0
Displays the values of the current analog
torque command
T
Analog Tq CMD -3000 3000

Table of Contents