Issue 2.0
4-22 Features and Specifications
GUIDE TO FEATURE PROGRAMMING
This guide provides a list of associated Programs that support this feature. .
Program
Number
Program Name/Description Input Data Default
10-12-01 GCD-CP10 Network Setup - IP Address
Should be set to 0.0.0.0 when using PRG 10-
12-09.
0.0.0.0 ~ 126.255.255.254
128.0.0.1 ~ 191.254.255.254
192.0.0.1 ~ 223.255.255.254
Default =
192.168.0.10
10-12-03 GCD-CP10 Network Setup – Default
Gateway
Assign the default gateway IP address for the
GCD-CP10.
0.0.0.0 ~ 126.255.255.254
128.0.0.1 ~ 191.254.255.254
192.0.0.1 ~ 223.255.255.254
Default = 0.0.0.0
10-12-09 GCD-CP10 Network Setup – IP Address
Set IP Address for GPZ-IPLE.
0.0.0.0 ~ 126.255.255.254
128.0.0.1 ~ 191.254.255.254
192.0.0.1 ~ 223.255.255.254
Default =
172.16.0.10
10-19-01 VoIP DSP Resource Selection
Select type of GPZ-IPLE DSP Resource. This
program setting has no affect on the terminal/
trunk port assignment or usage.
0 = Common use for both IP
extensions and trunks
1 = IP Extension
2 = SIP Trunk
3 = CCIS
4 = Use for NetLink
5 = Blocked
Resource 1 = 1
Resource
2 ~ 256 = 0
10-50-01 License Information – License Name
Read Only program used to confirm license
information that is stored in a system.
N/A
10-54-01 License Configuration for Each Package –
License Code
Assign VoIP resource licenses (5103) to the
GCD-CP10 slot (1).
1 ~ 255 resource licenses No Setting
10-68-01 IP Trunk Availability – Trunk Type
Set trunk type to CCISoIP for interconnecting
trunks.
0 = None
1 = SIP
2 = H.323
3 = CCIS
Default = 0
10-68-02 IP Trunk Availability – Start Port
Set the trunk port number to start the
assignment from.
0 ~ 400 Default = 0
10-68-03 IP Trunk Availability – Number of Ports
Set the number of ports to assign from the
starting point set in 10-68-02.
0 ~ 400 Default = 0
11-01-01 System Numbering – Service Code
The Call reroute feature only supports closed
numbering.
This program is used to customize the system
internal (Intercom) numbering plan.
Refer to the
Programming
Manual for
default values.

Table of Contents