Chapter 3 SETTINGS FOR FUNCTIONS
Chapter 3
Setting the Banks
3-43
ZW
User’s Manual
Setting the Banks
Changing the Bank Mode
Select the bank contents to be obtained from the settings or judgment value.
As an example, here is an explanation of the procedure for selecting the "Normal" bank
mode setting.
Operating procedure
Setting [Display] Description
Normal [NORMAL]
(Default value)
Sensing setting, measurement setting and I/O setting that are set in the FUN
mode are regarded as bank data.
The number of banks is up to eight.
Judgment [JUDGE] Only the threshold value under the measurement setting is regarded as bank
data.
The number of banks increases up to 32.
Steps
Key operation Display Description
1 Press key for two seconds to enter the FUN
mode.
2 Press or keys to select either of "BANK" and
press key.
3 Press or keys to select either of "BK.MODE"
and press key.
4 Select "Normal" as the bank mode.
The current setting value is displayed on the sub-
display.
Press / keys to enter the editing mode, and the
sub-display blinks.
Select "NORMAL" and press key.
5 Press key for two seconds to enter the RUN
mode.
RUN
FUN
TEACH
ZERORST/ZERORST/
ESCESC
ZERO/ZERO/
SETSET
ZERORST/
ESC
ZERO/
SET
RUN
FUN
TEACH