Chapter 7 APPENDIX
Chapter 7
Processing Item Data List
7-13
ZW
User’s Manual
Processing Item Data List
Unit 
number
Processing 
Item
Data 
numb
er
Palameter
Default 
value
Setting range/output 
range
Acq
uisiti
on 
ena
bled
/
disa
bled
Setti
ng 
ena
bled
/
disa
bled
0 Picture input 0 Mesured cycle 500 500 - 10000 (s) Yes No
22 2 area mode 0 0: OFF
1: ON
Yes Yes
23 Area tracking mode 0 0: No tracking
1: Track starting point
2: Track ending point
3: Track starting/ending 
points
Yes Yes
39 Surface subject to area 
tracking (Reference surface)
4 0: Edge 1st
1: Edge 2nd
2: Edge 3rd
3: Edge 4th
4: Light Peak
Yes Yes
40 Surface subject to area 
tracking (Tracking surface)
1 0: Edge 1st
1: Edge 2nd
2: Edge 3rd
3: Edge 4th
4: Light Peak
Yes Yes
193 2 area teaching - 1: Excecute No Yes
1 
(Note1)
Exposure 
Time Control
(2 area mode 
OFF)
0 Exposure Time Control 
Mode
0 0: Auto
1: Manual
Yes Yes
2 Surface subject to exposure 
time control
4 0: Edge 1st
1: Edge 2nd
2: Edge 3rd
3: Edge 4th
4: Light Peak
Yes Yes
6 Exposure time fixed value 1000 1 to 5000 (s) Yes Yes
14 Exposure time upper limit 1000 1 to 5000 (s) Yes Yes
36 Exposure time 1000 1 to 5000 (s) Yes No
37 Received light amount (1st) - 0 to 4095 (Gradation) Yes No
38 Received light amount (2nd) - 0 to 4095 (Gradation) Yes No
39 Received light amount (3rd) - 0 to 4095 (Gradation) Yes No
40 Received light amount (4th) - 0 to 4095 (Gradation) Yes No
20 Target to 
measure
1 Material 0 0: Normal
1: Mirror
2: Diffision
Yes Yes
4 Background removal level 100 0 to 4095 (Gradation) Yes Yes
(Note1) When using exposure time control with 2 area mode ON, 
- Area 1 exposure time control: Unit number "1"
- Area 2 exposure time control: Unit number "2"