Chapter 4 I/O SETTINGS
Chapter 4
Timing Charts
4-33
ZW
User’s Manual
Timing Charts
The following shows the timing charts when communication is performed with external
devices.
■ Basic operation
●
Explanation of operations
(1) During each sampling cycle, the LEDs are lit up and exposure is started.
(2) After the end of exposure, measurement starts.
(3) After the end of measurement, the judgment results and binary data are output.
(4) After the judgment results and binary data are output, the analog output is
updated.
(5) After the judgment results and binary data are output, the GATE signal is turned
ON.
(6) The GATE output time after the GATE signal is turned ON, the GATE signal is
turned OFF.
Item Minimum Maximum
T0 Measurement cycle 0.5 ms Depends on the set
conditions (0.5 to 30 ms)
T1 Exposure time 1 s Maximum exposure time
(1 to 5000 s)
T2 Response time of output T02T02
T3 Response time of analog output - 0.1 ms
T4 GATE signal rise time - 0.2 ms
T5 Output time of GATE signal Setting value
(0.1 to 100.0 ms)
Setting value
(0.1 to 100.0 ms)
(2) (3) (5) (6)
T5
(4)
T0
(1)
T1 T2
T4
T3
ON
OFF
ON
OFF
Exposure
Judgment output
(HIGH/PASS/LOW)
Binary output
GATE output
Analog output