7-14
Chapter 7 APPENDIX
ZW
User’s Manual
Chapter 7
Processing Item Data List
40 Measuring
point
0 Measured item
1:
TASK1
0:
TASK2 to 3
0: None
1: Height
2: Thick
3: Calculation
Yes Yes
1 Measurement Surface 1 4 0: Edge 1st
1: Edge 2nd
2: Edge 3rd
3: Edge 4th
4: Light Peak
Yes Yes
2 Measurement Surface 2 4 0: Edge 1st
1: Edge 2nd
2: Edge 3rd
3: Edge 4th
4: Light Peak
Yes Yes
3 Parameter X 0 0: None
1: TASK1
2: TASK2
3: TASK3
4: TASK4
Yes Yes
4 Parameter Y 0 0: None
1: TASK1
2: TASK2
3: TASK3
4: TASK4
Yes Yes
5 Parameter K 0 -999999999 to
999999999
Yes Yes
6 Parameter m 0 -100 to 100 (1div: 0.1) Yes Yes
7 Parameter n 0 -100 to 100 (1div: 0.1) Yes Yes
13 Measuring area 0 0: Area1
1: Area2
Yes Yes
41 Scaling 2 Scaling mode 0 0: Off
1: Height auto
2: manual
3: Thick auto
Yes Yes
3 Span value 10000 -20000 to 20000 (1div:
0.1)
Yes Yes
4 Offset value 0 -999999999 to
999999999 (nm)
Yes Yes
42 Median 2 Median filter mode 0 0: Off
1: Count 3
2: Count 9
3: Count 15
Yes Yes
Unit
number
Processing
Item
Data
numb
er
Palameter
Default
value
Setting range/output
range
Acq
uisiti
on
ena
bled
/
disa
bled
Setti
ng
ena
bled
/
disa
bled