EasyManuals Logo

Omron ZW Series User Manual

Omron ZW Series
247 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #165 background imageLoading...
Page #165 background image
Chapter 4 I/O SETTINGS
Chapter 4
Timing Charts
4-37
ZW
User’s Manual
(Caution)
When the setting for non-measurement is "Clamp", if the sampling value is an abnormal value or an
undetermined value *, sampling is not executed. If sampling has been started, it is stopped. The output
value is as follows.
- The clamp value is held.
- If the previous hold value is not the clamp value, the GATE signal is output.
- The BUSY signal is turned OFF.
To start and continue sampling even if a sampling value is an abnormal value or an undetermined value,
set "Keep" as the non-measurement setting.
* After the start of measurement, if measurement results are not obtained the number of times required to
take the average, the measurement result is not applied.

Table of Contents

Other manuals for Omron ZW Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron ZW Series and is the answer not in the manual?

Omron ZW Series Specifications

General IconGeneral
BrandOmron
ModelZW Series
CategoryAccessories
LanguageEnglish

Related product manuals