EasyManuals Logo

Omron ZW Series User Manual

Omron ZW Series
247 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #215 background imageLoading...
Page #215 background image
Chapter 6 SPECIFICATIONS AND EXTERNAL DIMENSIONS
Chapter 6
Controller
6-9
ZW
User’s Manual
External
interface
52-pole
extension
connector
Bank Selected
bank output
(BANK_OUT
1 - 3)
Transistor output system
Output voltage: 21.6 to 30 VDC
Load current: 50 mA or less
Residual voltage when turning ON: 1.2 V or less
Leakage voltage when turning OFF: 0.1 mA or less
Selected
bank input
(BANK_SEL
1 -3)
DC input system
Input voltage: 24 VDC ±10 % (21.6 to 26.4 VDC)
Input current: 7 mA Typ. (24 VDC)
Voltage/Current when turning ON: 19 V/3 mA or more
Voltage/Current when turning OFF: 5 V/1 mA or less
Main
functions
Exposure time Auto/Manual
Measuring cycle 500 m to 10 ms
Material setting Standard/Mirror/Diffusion surfaces
Measurement Item Height/Thickness/Calculation
Filtering Median/Average/Differentiation/High pass/Low pass/Band
pass
Outputs Scaling/Different holds/Zero reset/Logging for a measured
value
Display Measured value/Threshold value/Analog output voltage or
current value/Judgment result/Resolution/Exposure time
Number of configurable banks Max. 8 banks
Task process Multi-task (up to 4 tasks per bank)
System Save/Initialization/Display measurement information/
Communication settings/Sensor Head calibration/Key-lock/
Trigger-key input
Ratings Power supply voltage 21.6 V to 26.4 VDC (including ripple)
Current consumption 500 mA max.
Insulation resistance Across all lead wires and controller case: 20 M (by 250 V
megger)
Dialectic strength Across all lead wires and controller case: 1,000 VAC, 50/60
Hz, 1 min
Environme
ntal
immunity
Degree of protection IP20 (IEC60529)
Vibration resistance (destructive) 10 to 55 Hz, 0.35-mm single amplitude, 50 min each in X, Y,
and Z directions
Shock resistance (destructive)
150 m/s
2,
3 times each in six directions (up/down, left/right,
forward/backward)
Ambient temperature Operating: 0 to +40 °C
Storage: -15 to +60 °C (with no icing or condensation)
Ambient humidity Operating and storage: 35 % to 85 % (with no condensation)
Grounding D-type grounding (Grounding resistance of 100 or less)
Note: For conventional Class D grounding
Materials Case: PC
Weight Approx. 750 g (main unit only)
Accessories Instruction
sheet,
Member
registration
sheet
Instruction
sheet,
Member
registration
sheet and
software for
setting (CD-
ROM)
Instruction
sheet,
Member
registration
sheet
Instruction
sheet,
Member
registration
sheet and
software for
setting (CD-
ROM)
Item
Specifications
ZW-C10T ZW-C10AT ZW-C15T ZW-C15AT

Table of Contents

Other manuals for Omron ZW Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron ZW Series and is the answer not in the manual?

Omron ZW Series Specifications

General IconGeneral
BrandOmron
ModelZW Series
CategoryAccessories
LanguageEnglish

Related product manuals