Chapter 6 SPECIFICATIONS AND EXTERNAL DIMENSIONS
Chapter 6
Controller
6-9
ZW
User’s Manual
External
interface
52-pole
extension
connector
Bank Selected
bank output
(BANK_OUT
1 - 3)
Transistor output system
Output voltage: 21.6 to 30 VDC
Load current: 50 mA or less
Residual voltage when turning ON: 1.2 V or less
Leakage voltage when turning OFF: 0.1 mA or less
Selected
bank input
(BANK_SEL
1 -3)
DC input system
Input voltage: 24 VDC ±10 % (21.6 to 26.4 VDC)
Input current: 7 mA Typ. (24 VDC)
Voltage/Current when turning ON: 19 V/3 mA or more
Voltage/Current when turning OFF: 5 V/1 mA or less
Main
functions
Exposure time Auto/Manual
Measuring cycle 500 m to 10 ms
Material setting Standard/Mirror/Diffusion surfaces
Measurement Item Height/Thickness/Calculation
Filtering Median/Average/Differentiation/High pass/Low pass/Band
pass
Outputs Scaling/Different holds/Zero reset/Logging for a measured
value
Display Measured value/Threshold value/Analog output voltage or
current value/Judgment result/Resolution/Exposure time
Number of configurable banks Max. 8 banks
Task process Multi-task (up to 4 tasks per bank)
System Save/Initialization/Display measurement information/
Communication settings/Sensor Head calibration/Key-lock/
Trigger-key input
Ratings Power supply voltage 21.6 V to 26.4 VDC (including ripple)
Current consumption 500 mA max.
Insulation resistance Across all lead wires and controller case: 20 M (by 250 V
megger)
Dialectic strength Across all lead wires and controller case: 1,000 VAC, 50/60
Hz, 1 min
Environme
ntal
immunity
Degree of protection IP20 (IEC60529)
Vibration resistance (destructive) 10 to 55 Hz, 0.35-mm single amplitude, 50 min each in X, Y,
and Z directions
Shock resistance (destructive)
150 m/s
2,
3 times each in six directions (up/down, left/right,
forward/backward)
Ambient temperature Operating: 0 to +40 °C
Storage: -15 to +60 °C (with no icing or condensation)
Ambient humidity Operating and storage: 35 % to 85 % (with no condensation)
Grounding D-type grounding (Grounding resistance of 100 or less)
Note: For conventional Class D grounding
Materials Case: PC
Weight Approx. 750 g (main unit only)
Accessories Instruction
sheet,
Member
registration
sheet
Instruction
sheet,
Member
registration
sheet and
software for
setting (CD-
ROM)
Instruction
sheet,
Member
registration
sheet
Instruction
sheet,
Member
registration
sheet and
software for
setting (CD-
ROM)
Item
Specifications
ZW-C10T ZW-C10AT ZW-C15T ZW-C15AT