Verify NVMe Cable Connections
checking pcie link on drive NVMe 11 OK
NVME drives pcie link check: PASSED
Checking NVME drive DSN...
checking DSN on drive NVMe 0 OK
checking DSN on drive NVMe 1 OK
checking DSN on drive NVMe 2 OK
checking DSN on drive NVMe 3 OK
checking DSN on drive NVMe 4 OK
checking DSN on drive NVMe 5 OK
checking DSN on drive NVMe 6 OK
checking DSN on drive NVMe 7 OK
checking DSN on drive NVMe 8 OK
checking DSN on drive NVMe 9 OK
checking DSN on drive NVMe 10 OK
checking DSN on drive NVMe 11 OK
NVME drives DSN check: PASSED
Checking NVME cabling...
Cables associated with Switch Card 0 in PCIe Slot 3 verified
Cables associated with Switch Card 1 in PCIe Slot 4 verified
Cables associated with Switch Card 2 in PCIe Slot 8 verified
Cables associated with Switch Card 3 in PCIe Slot 9 verified
NVME cable check: PASSED
NVME test PASSED
diag>
If any of the tests fail, there could be a problem with the cabling. For example:
â–
If a cable is crossed (plugged into the incorrect port), then the NVMe drive DSN (Drive
Serial Number) test should report two drives where the DSN does not match. The cabling
for those drives should be inspected to ensure that it is correct.
â–
If multiple NVMe drive PCIe links are not active, or multiple NVMe drive DSNs are not
OK, then check the Port 2 connection on the NVMe switch card. If Port 2 is incorrectly
cabled, it could affect all three drives that are connected to that NVMe switch card.
7.
Once issues are resolved, power cycle the system by removing the power cords
from the power supplies, waiting 30 seconds, and then reattaching the power
cords.
8.
Retest the system by repeating Step 1 through Step 6.
Once all NVMe cable connection tests have passed, the server operating system can be booted.
202 Oracle Server X8-2L Service Manual • January 2021