Maintenance Console Location
9.4 PBX Configuration—[1-1] Configuration—Slot—System Property
RAS Port Number
Specifies the port number for the H.225 protocol
(RAS) in an H.323 protocol suite.
Default
1719
Value Range
1–65535
Maintenance Console Location
9.4 PBX Configuration—[1-1] Configuration—Slot—System Property
QSIG Connectionless Tunneling TCP Port Number
Specifies
the TCP port number for connectionless tunneling between gateway devices at different locations in
a QSIG network.
Default
1718
Value Range
1–65535
Maintenance Console Location
9.4 PBX Configuration—[1-1] Configuration—Slot—System Property
QSIG Connectionless Tunneling UDP Port Number
Specifies the UDP port number for connectionless tunneling between gateway devices at different locations
in a QSIG network.
Default
1717
Value Range
1–65535
Maintenance Console Location
9.4 PBX Configuration—[1-1] Configuration
—Slot—System Property
H.323 Dynamic Port Number
Specifies the starting port number from which 448 contiguous ports are used as dynamic ports.