EasyManua.ls Logo

Panasonic KX-NS1000 - Page 228

Panasonic KX-NS1000
1294 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
GW Settings–Option 1
GW Name
Specifies the name of the destination gateway device for programming reference.
Default
Not stored
Value Range
Max. 20 characters
Maintenance Console Location
9.4 PBX Configuration—[1-1] Configuration
—Slot—System Property
IP Codec Priority—1st, 2nd, 3rd
Specifies the priority of the codecs to be used. For fax communications, it is necessary to specify G.711A or
G.711Mu for 1st priority.
Default
1st: G.729A
2nd: None
3rd: None
Value Range
For 1st:
G.711A, G.711Mu, G.729A
For 2nd and
3rd:
None, G.711A, G.711Mu, G.729A
Maintenance Console Location
9.4 PBX Configuration—[1-1] Configuration—Slot—System Property
Packet Sampling Time (G.711A)
Specifies
the time interval between measurements (samples) of sound data during a conversation. The smaller
this number, the higher the quality of the transmitted sound.
Default
20 ms
Value Range
20 ms, 30 ms, 40 ms, 50 ms, 60 ms
Maintenance Console Location
9.4 PBX Configuration—[1-1] Configuration—Slot—System Property
228 PC Programming Manual Document Version 2016-03
9.4 PBX Configuration—[1-1] Configuration—Slot—System Property

Table of Contents

Other manuals for Panasonic KX-NS1000

Related product manuals